Eppendorf CellXpert® C170i Incubator

Essential for maintaining optimal environmental conditions
Personalise
2025-01-28-eppendorf-co2-incubator

Description

The Eppendorf CellXpert C170i cell culture incubator is essential for maintaining optimal environmental conditions for the growth and preservation of cell cultures in research and clinical laboratories.

Specifications

  • Effective contamination protection: 140 °C sterilization routine
  • Uniform atmosphere: Dual-channel IR-sensor (no TC-sensor), temperature uniformity verified (ISO 12880:2007-05),
  • Atmosphere controller: DCI temperature and CO2 recovery after door opening (< 5 min)
  • Easy cleaning: Stainless-steel chamber without seams, Enhanced vibration and turbulence protection: No fan inside, Low gas consumption: <1 L CO2/24 h (5 % CO2, w/o door opening)
  • Capacity: 170 L (6.0 ft³)
  • Temperature range: Ambient +4 °C to 50 °C
  • Temperature control increment: ±0.1 °C
  • Temperature stability at 37 °C: ±0.1 °C
  • CO2 range: 0.1–20%

Publishing Data Acquired using the Eppendorf CellXpert C170i CO2 Incubator

      • Cell seeding density
      • Medium composition
      • Incubation conditions
      • Manufacturer: Eppendorf
      • Model: CellXpert C170i
      • Type: CO2 Incubator
      • Temperature (°C)
      • CO2 concentration (%)

    Acknowledgement:

    “The authors acknowledge the facilities and the scientific and technical assistance of Cell Culture Facility (CCF) within the Mark Wainwright Analytical Centre (MWAC) at UNSW Sydney.”

    Credit MWAC CCF staff: Feel free to mention MWAC CCF staff who have assisted you with your work! If staff have been involved with your work beyond basic training and support (e.g., project design, complex data/image processing, independent imaging/analysis, manuscript preparation), it may be appropriate to discuss co-authorship with the relevant staff and your supervisor.

Applications

  • Tissue culture
  • Cytotoxic reagent incubation
  • Nanoparticle incubation
  • Primary Cell culture Incubation

Instrument location

MWAC Cell Culture Facility

Room 524, Science and Engineering Building (SEB) – E8
Kensington, UNSW, Sydney,
NSW, 2052

Email: CCFAdmin@unsw.edu.au

Access

For access to the MWAC Cell Culture Facility
  • Send email envelope icon
    Email
    CCFAdmin@unsw.edu.au

Explore more instruments, facilities & services

Our infrastructure and expertise are accessible to UNSW students and staff, external researchers, government, and industry.